On the "Tools" menu there is an item for "Test Interface", this allows the basic interface communications to be tested.
Note: The following only applies to the Mitsubishi USB / LOGBOX / LOGBOX PRO v2 interfaces.



To Test Flashing Mode
1. Ensure the interface is NOT plugged into an ECU.
2. Ensure you have the Interface powered with 12v connected to pin 5 and Ground connected to pin 8 on the Interface.
If you have a bench harness to suit the Mitsubishi Interface you can connect the 8 pin molex connector and power supply.

If you only have a power supply you can connect to the interface as below.

3. Connect the USB cable from the Interface to the computer.
4. Move the mode switch on the interface to the right hand side position to the Read / Write mode (Red Led on).
5. Open the Woolich Racing Tuned Software, go to "Tools" then to "Test Interface".

6. Click Test Interface.

Voltage Tests on Mitsubishi v2 Interfaces ONLY
Use a multimeter in a DC voltage setting to perform the following tests.
1. Connect the USB cable from the Interface to the computer.
2. Move the mode switch on the interface to the right hand side position to the Read / Write mode (Red Led on).
3. Connect the Interface with a 12v power supply either by the bike ignition with an on bike harnesses or with the 12v power supply using a bench harnesses connected to the 8 pin molex connector. Ensure the interface is NOT plugged into an ECU.
4. Measure the voltage between pin 3 and pin 8 on the interface, this should be 11.5v -13.5v when in flashing mode (Red LED on).
5 . Measure the voltage between pin 4 and pin 8 on the interface, this should be 14.0v - 16.0v when in flashing mode (Red LED on).
The plug pin out above is the 8 pin Molex plug on the Interface
Was this helpful?